Flyability Knowledge Base
WebsiteMy dronesCloudContact support
  • New articles and updates
  • Important Communication
  • Aircraft
    • Elios 3
      • Elios 3 Documentation
        • Elios 3 Certificates
      • Elios 3 System update
      • Elios 3 Cockpit App
        • Cockpit 3 How to update
        • Cockpit 3 Release notes
      • Elios 3 Payload
        • Surveying payload
          • Surveying Payload Quick Start Guide
          • Surveying payload Tecnical specifications
          • Surveying payload Accuracy report
        • UT Payload
          • UT Payload Quick Start Guide
        • Flammable Gas sensor
          • Flammable Gas Sensor Quick Start Guide
        • Radiation sensor
      • Elios 3 Maintenance
      • Elios 3 Feature details
        • Elios 3 LED patterns
        • Elios 3 Return To Signal - User Guide
        • Elios 3: How to connect the tablet on a computer
        • Elios 3 Return To Home - User Guide
      • Elios 3 Troubleshooting
        • Elios 3 Warning messages
        • Elios 3 Retrieve data for support
      • Elios 3 Training simulator
    • Elios 2
      • Elios 2 Documentation
      • Elios 2 System updates
        • Elios 2 Release note
      • Elios 2 Cockpit App
        • Cockpit 2 How to update
        • Cockpit 2 Release notes
      • Elios 2 Maintenance
      • Elios 2 Feature details
        • Elios 2 Remote controller stick calibration
        • Elios 2 Downgrade the remote controller firmware
        • Elios 2 Configure HDMI output for secondary monitor
        • Elios 2 LED patterns
        • Elios 2 How to test the transmission system
        • Elios 2 When to use the ATTI flight mode
      • Elios 2 Troubleshooting
        • Elios 2 Warning messages
        • Elios 2 Remote controller is beeping and red LED flashes
      • Elios 2 Mission and Flying
        • Mission preparation
        • Flight planning and analysis process
        • How much flight time is needed for an inspection
      • Elios 2 Training
        • Elios 2 Training simulator
    • Elios 1
      • Elios 1 Documentation
      • Elios 1 System update
      • Elios 1 Cockpit App
        • Cockpit 2 How to update
        • Cockpit 2 Release notes
      • Elios 1 Maintenance
      • Elios 1 Feature details
      • Elios 1 Troubleshooting
        • Elios 1 Bind the remote controller
        • Elios 1 Configure HDMI output for secondary monitor
        • Elios 1 Remote controller stick calibration
        • Elios 1 How to test the transmission system
        • Elios 1 Tablet not connecting to the remote controller
        • Elios 1 Remote controller is beeping and red LED flashes
        • Elios 1 Downgrade the remote controller firmware
      • Elios 1 Training
  • ACCESSORY
    • Range extender
  • SOFTWARE AND CLOUD
    • Inspector
      • Inspector 5
        • Software - Quick Start Guide
          • Inspector 5 - Quick Start Guide
          • Asset Management - Quick Start Guide
        • Common workflows
          • How to connect Elios 3 to Inspector 5
          • Inspector 5 - Data Management Workflows - Exporting and Sharing Data
          • Retrieve previous flight data from your Elios 3 since 2024 April update
          • How to retrieve the Inspector 5 Logs
      • Inspector 3/4
      • Inspector 2
      • Complementary information
        • Required Remote URLs and Ports
    • Cloud
      • Cloud Quick Start Guide
      • Cloud FAQ
      • Cloud How to videos
      • Cloud Release Notes
  • THIRD PARTY SOFTWARE
    • FARO Connect
      • Software
        • System Requirements
        • How to Install FARO connect
        • Download - Current FARO Connect and Flyability script installer
        • File formats used by FARO connect
        • Known limitations
        • GeoSLAM Connect (end of life)
        • Available Training
      • First Project - How to process a point cloud
    • Wincan
  • Complementary information
    • Technical information
      • Lithium Battery Terminology
    • Spare parts and maintenance
      • Repair the cage
      • Buy a new tablet
    • Transport and shipping
      • Send your drone to Flyability
      • Air travel with Flyability drones and batteries
  • Policy & Security
    • Cybersecurity with Flyability products
    • Product warranty
      • Elios 3 warranty
      • Elios 2 warranty
      • Elios 1 warranty
    • Europe Flying Regulations
      • B-RID for Elios 3 mounting instructions
      • B-RID for Elios 2 mounting instructions
Powered by GitBook
On this page
  • Before Starting
  • Unboxing the Payload
  • Software requirements
  • Setting up your Flammable Gas Sensor
  • Mounting the Flammable Gas Sensor
  • Getting ready for your first flight
  • Preparation
  • Initializing the flammable gas sensor
  • Setting the threshold limits
  • Performing a bump test

Was this helpful?

Export as PDF
  1. Aircraft
  2. Elios 3
  3. Elios 3 Payload
  4. Flammable Gas sensor

Flammable Gas Sensor Quick Start Guide

Discover everything you need to know to get started with your Elios 3 Flammable Gas Sensor

Last updated 1 month ago

Was this helpful?

Before Starting

Unboxing the Payload

When you have received your new Flammable Gas Sensor, make sure that the package is not damaged externally. If any substantial damage can be seen, contact our customer support team () before opening it.

Although it is protected, please do not use something sharp that could damage the Payload while opening the package.

Disclaimers

Carefully read the Elios 3 Flammable Gas Sensor User Manual and Quick Start Guide before managing the equipment and performing a flight.

Important Safety Notice on the Use of the Flammable Gas Sensor

1. Elios 3 is Not Intrinsically Safe

This drone is not safe for use in environments with known flammable gas. Do not operate in areas with potential gas presence.

2. Airflow Impact on Measurement

The drone's airflow can alter gas concentration, affecting sensor accuracy. Readings should be considered approximate.

3. Sensor as a Safety Aid

The gas sensor is a safety aid, not a precise gas leak detection or quantification tool.

4. Follow Safety Protocols

The sensor does not replace standard safety procedures. Always follow proper protocols for flying in potentially hazardous environments.

By mounting and using the Flammable Gas Sensor by Flyability, you accept these limitations and full responsibility for the drone's operation and any resulting consequences. Flyability is not liable for any damage, injury, or loss incurred during use.

Software requirements


Setting up your Flammable Gas Sensor

Mounting the Flammable Gas Sensor

The Flammable Gas Sensor is ONLY compatible with the Elios 3. The Elios 1 and Elios 2 drones cannot be equipped with this Payload.

To mount the Payload you will need a T8 screwdriver, a T6 screwdriver, the included mount, the Gas Sensor, the included M 2.5x10 screw, and the included M2 screws (3). Watch this video to learn more about how you can mount your new Flammable Gas Sensor on the Elios 3 drone:


Getting ready for your first flight

Preparation

Now that the Flammable Gas Sensor has been mounted, all the systems have been updated, you have performed a bump test, and you have read the user manual, it is time for you to familiarize yourself with the new Cockpit settings.

Initializing the flammable gas sensor

The first thing you need to do is initialize the gas sensor. To do so, click on the green button that is on the gas sensor gauge on Cockpit as shown in the photo below:

This process may take up to 90 seconds. Once complete the status will switch to OK.

Setting the threshold limits

The second thing you will need to do is set the threshold limits. These thresholds (2) refer to the set levels at which the sensor triggers an alert on the Cockpit and Remote Controller based on the concentration of a detected gas. If these thresholds are met Cockpit will flash red, emit a warning sound, and the Remote Controller will start vibrating. You can set two thresholds, for warning and critical levels. To do so, open Settings on Cockpit and select the GAS tab.

Please make sure the tablet is in ring mode to hear the alarms.

Performing a bump test

A bump test is performed on a gas sensor to ensure that it is functioning properly and can accurately detect and respond to the presence of specific gases. It involves briefly exposing the sensor to a known concentration of test gas to confirm that it responds within the expected range. This test is a critical part of regular sensor maintenance and safety protocols and should be done before every inspection.

To perform a bump test you will need a Calibrated Bottle of the correct gases, the Elios 3 with the Flammable Gas Sensor plugged in, the provided bump test tool, and the Remote Controller of the drone. Watch this video to learn how you can perform a bump test on the Elios 3 Flammable Gas Sensor:

PLEASE NOTE! Make sure the Calibrated Bottle contains the gas most relevant for your application and that the LEL level of the calibrated gas is over the threshold you want to set. Readings may take up to 12 seconds to be displayed and 30 seconds to show the correct levels of LEL. Confirm that the alarms are triggered once the LEL levels go over the threshold.

Your Flammable Gas Sensor for Elios 3 is now ready.

To use your new Payload you must update Cockpit and your Elios 3 to the latest version (2024.10 or later). See more on how to update Cockpit. To update your drone simply connect it to your PC while connected to the internet and you will receive a pop-up prompting you to update your drone.

support@flyability.com
here
Initialize gas sensor
Setting the thresholds